Ac Pcb Assy - MIMAKI JV300-130 Maintenance Manual

Hide thumbs Also See for JV300-130:
Table of Contents

Advertisement

MAINTENANCE MANUAL > Electrical Parts > Circuit Board Specifications > AC PCB Assy
Model
JV300-130/160
Issued 2014.05.30 Revised

2.3.4 AC PCB Assy

CN3
 Outline
Board name: AC PCB Assy.(E107795)
This PCB control the heaters. 100V/200V is switched with this PCB.
 Input and output of the power source
Input
AC100-120V, AC220-240, 50/60Hz
Output
+5V
 Connector specification
No.
Pin
CN1
4
DF22-4P-7.92DSA(05) AC input
CN2
4
B04P-VL-VN-1.8
CN3
6
B06P-VL
CN4
6
B06P-VL
CN5
6
B06P-VL
CN6
4
B04P-VL
CN7
4
B04P-VL
CN8
4
B04P-VL
CN9
5
B5B-PH-K-S(LF)(SN)
 Fuse rating
F1
50T-125H
F3
50T-125H
© 2014 MIMAKI ENGINEERING CO.,LTD.
CN1
CN6
F2
CN7
CN2
Type
Intended use
Jumper
(For 150/300 switching)
Pre-Heater
Print-Heater
Print-Heater
After-Heater
SSR(Pre, After)
SSR(Print)
Voltage change SW input
Zero cross point output
5x20 mm
For 12.5A, AC protect
x0 mm
For 12.5A, AC protect
F/W ver.
1.00
Remark
CN4
F1
CN8
AC/DC
AC
AC
AC
AC
AC
AC
AC
AC
DC
Rev.
1.0
CN5
CN9
Remarks
2.3.4
R.1.0
1
2
3
4
5
6
7
8
P.1