4.2.9 MAINT. WASH

 Outline
Fill up washing liquid for the sequence to apply it at station maintenance.
 Procedure
FUNCTION
#ADJUST
[ENT]
#ADJUST
MAINT. WASH
[ENT]
CART:ON END:OFF
EXECUTE
[ENT]
PLEASE WAIT
** CLEANING **
PLEASE WAIT
© 2014 MIMAKI ENGINEERING CO.,LTD.
F/W ver.
1.00
1. When you perform filling, insert the washing liquid cartridge
into the washing liquid slot.
2. When you discharge, remove it.
3. Select [#ADJUST][MAINT. WASH] from the operation menu.
4. Press the [ENTER] key, and then the valve is released and the
pump rotates.
5. Perform cleaning operation and terminate with [END] key.