4.2.6 CAPPING

 Outline
Adjusts the location for capping. Adjusted value is saved in the system parameter.
Basically, it is not necessary to make adjustment even when cap (and the like) has been replaced.
 Adjustment procedure
FUNCTION
#ADJUST
[ENT]
#ADJUST
CAPPING
[ENT]
#CAPPING
CAPPING POS=
2.0
#CAPPING
AirPullPOS.=
2.0
#CAPPING
FlushingPOS=
2.0
© 2014 MIMAKI ENGINEERING CO.,LTD.
1. Select [#ADJUST] - [CAPPING].
2. Make adjustment so that the cap slider is located at 3 mm to the
3 mm
right from the uppermost point it has reached on the cap base.
3. Make adjustment so that the clearance between the head and
uppermost point of the cap is set at 0.5 mm.
4. Make adjustment so that the clearance between the head and
uppermost point of the cap is set at 1 mm.
F/W ver.
1.00
Remark
[] / []: Horizontally shifts the cap.
[ENTER]: Finalizes (To Next)
[] / []: Shifts the cap.
[ENTER]: Finalizes (To Next)
[] / []: Shifts the cap.