MAINTENANCE MANUAL > Disassembly and Reassembly > Ink-related Parts > Selective Path Pump Assy
Model
JV300-130/160
Issued 2014.05.30 Revised
6.2.4 Selective Path Pump Assy
Work procedures
Turn the main power OFF when turning the power OFF. It is very dangerous if sleep mode functions
mistakenly during the operation.
Be sure to wear protective glasses and working gloves during the operation.
Ink may get into your eyes depending on the working condition, or hand skin may get rough if you touch
the ink.
Cap1 and 2 side
Connector
© 2014 MIMAKI ENGINEERING CO.,LTD.
1. Remove the Under cover R, Cover R and Cover R2.
2. Remove the tubes from the Cap1 and Cap2, remove the Fit-
ting connected to the pump tube.
3. Remove the pump tube connected to the waste ink tank.
Remove tube
4. Remove the connector.
F/W ver
1.00
Remark
Selective path Assy
Take care not to pollute the surroundings with waste
ink or washing liquid.
Take care not to pollute the surroundings with waste
ink or washing liquid.
Rev.
1.0
1
2
3
4
5
6
7
8
6.2.4
R.1.0
P.1