4.2.15 POINTER OFFSET
Function
Print the adjustment pattern and adjust the location of the LED pointer and print origin (Nozzle A Column).
Procedure
FUNCTION
#ADJUST
[ENT]
#ADJUST
POINTER OFFSET [ENT]
© 2014 MIMAKI ENGINEERING CO.,LTD.
1. Select [#ADJUST] - [POINTER OFFSET].
2. Make necessary adjustments.
After drawing is completed
[], [], [], [] : LED pointer movement
LED Pointer
F/W ver.
1.00
Remark
[ENTER]: Starts drawing.
Align the LED pointer to the pattern position
shown on the left (intersection of the straight
lines).
[ENTER]: Settings
[END]: Cancellation of input
This function perform adjusting only once.
When drawing is performed, readjustment is
necessary because adjustment value is reset.