How To Change The Displayed Language; Special Functions - GRAPHTEC FC 4500 Series Service Manual

Cutting plotter
Hide thumbs Also See for FC 4500 Series:
Table of Contents

Advertisement

3.2

How to change the displayed language

The menus of this plotter are displayed in English (Alphabet) by the factory setting.
If necessary, change the English display to Japanese (Kata-kana) display using the following procedure:
Turn the power on while pressing the F1 key : Display in Japanese (Kata-kana)
Turn the power on while pressing the F3 key : Display in English (Alphabet)
Or you can select the language at the language selecting in the special menu.
3.3

Special Functions

Setting the Display Language (LANGUAGE SELECTION) [Default setting: ENGLISH]
This function determines the language used on the display panel.
Setting the Length Unit (LENGTH UNIT) [Default setting: mm]
This function enables the display unit shown on the LCD panel to be changed.
If "mm" is selected, the values are displayed in millimeter units.
If "inch" is selected, the values are displayed in inch units.
Enabling or Disabling the ":" and ";" Commands (;,:COMMAND) [Default value: ENABLED]
When the GP-GL command mode is selected, this function enables or disables the recognition of ":" and ";"
commands sent from the computer. If the first part of the transmitted data is missing, the problem might be
attributable to these commands. In such cases, set this function to DISABLED.
Moving the Tool in the Raised or Lowered Status after the "W" Command is Sent
(W COMMAND) [Default setting: TOOL UP]
When a GP-GL "W" command specifying the creation of a circle or arc is sent from the computer, this func-
tion determines whether to move the tool to the starting position for cutting in the raised status or whether to
leave it in the status it was in prior to receipt of the command.
When TOOL DOWN is selected, the tool is moved to the starting position in the status (raised or lowered) it
was in before receipt of the "W" command.
When TOOL UP is selected, the tool is raised before moving to the starting position.
These settings are effective in the cutting mode only.
Model No. Response (MODEL EMULATE) [Default setting: 7595]
TM
When the HP-GL
command mode is selected, this function determines the plotter's response to an "OI"
request sent from the computer.
When 7550 is selected, the plotter's response is 7550B.
When 7595 is selected, the plotter's response is 7595A.
FC4500-UM-251-9370
3 THE TREE STRUCTURE OF MENUS
11

Advertisement