(19) Calculate the adjustment values by the following calculation formula.
X adjustment value = (500 - (Measured distance of X)) x 100
Y adjustment value = (400 - (Measured distance of Y)) x 100
L adjustment value = Measured distance of L
For example:
X measured distance is 500.1mm, Y measured distance is 399.8 mm
X adjustment value:
-10 = (500-500.1) x 100
Y adjustment value:
+20 = (400-399.8) X 100
(20) Press the [F4] key to display the adjustment values input menu from the following menu.
(21) The following menu is displayed. Then input the adjustment values for the X and the Y.
Each keys are corresponding to the following operations.
F1 Key:
F2 Key:
F3 Key:
F4 Key:
(22) Press the [Enter] key after the X and the Y adjustment values were input.
The following menu is displayed. Then input the adjustment values for the L.
Each keys are corresponding to the following operations.
F1 Key:
F2 Key:
F3 Key:
F4 Key:
FC4500-UM-251-9370
FORCE
F1
ORIGINAL
ADJ.DRAW
F2
SPEED
FORCE
F1
DIST. ADJ.(0.01mm)
X =+10
F2
SPEED
Increasing the X adjustment value by 0.01 mm step
Decreasing the X adjustment value by 0.01 mm step
Increasing the Y adjustment value by 0.01 mm step
Decreasing the Y adjustment value by 0.01 mm step
FORCE
F1
+0.1
+0.01 L=640.31 -0.01
F2
SPEED
Increasing the L adjustment value by 0.1 mm step
Increasing the L adjustment value by 0.01 mm step
Decreasing the L adjustment value by 0.1 mm step
Decreasing the L adjustment value by 0.01 mm step
OFFSET
CLEAR
INPUT
QUALITY
OFFSET
Y =-10
QUALITY
OFFSET
X-Y LENG
-0.1
QUALITY
130
7 ELECTRICAL SECTION
F3
F4
F3
F4
F3
F4