Repair and Adjustment Procedures
[4]
4. Remove aligner latch stop by removing screws [4]
[3]
[3]
[5]
5. Remove the shaft nylon bushings [3].
6. Lift the Aligner panel up and unhook the tension spring from the panel [5].
7. Remove the Aligner panel out the front of the punch.
8. Reverse the steps to install the Aligner panel.