Maintenance Schedule
Inspect and clean every 750K cycles.
Procedure
Inspect for wear patterns or groves. The roller surface should be even and not
glazed.Clean with a soft cloth and alcohol.
Tools Required
Phillips screw driver or 1/4" nut driver
Flat bladed screwdriver
Needle nose pliers
Remove the Punch Module Assembly first, using procedure
Removal"
on page 4-49. With the Punch Module out of the machine, the punch
entrance side [1] and exit [2] drive rollers can be cleaned or replaced.
[1]
To clean the punch entrance drive rollers:
1. Remove the idler roller assembly [1].
2. Rotate and clean the drive rollers [2].
[1]