Section 4
4.5.1 Idler Roller Removal
4-16
This procedure refers to the idler rollers [3] shown in
as assemblies.
Note: This procedure does not apply to the Aligner panel idler rollers. See
Panels"
on page 4-17.
1. Lift the retaining spring [1] over the end of the idler roller shaft.
Figure 4.17 Releasing Idler Roller Retaining Spring.
2. Pull the released shaft end out of the bushing fork [2], releasing the opposite
end of the shaft from the other retaining spring.
3. To install idler roller assemblies reverse the steps.
Installation Note:
•
Make sure the flat surface of the bushing aligns in the fork.
•
Rollers are non-directional so it does not matter which end goes in each fork.
•
After the assembly is in place, gently pull the assembly outward and release
to ensure it moves freely in the fork.
© Copyright 2009 GBC. All rights reserved.
Figure 4.16
that are easily removed
"Aligner
Advanced Punch Service Manual
[1]
[2]