Aligner Latch Inspection - GBC AdvancedPunch Technical & Service Manual

Table of Contents

Advertisement

1.4.14 Aligner Latch Inspection

Advanced Punch Service Manual
Latches [1] on both sides of the punch hold the Aligner Panels in place, which in
turn keeps even pressure on the idler rollers.
Maintenance Schedule
Inspect every 750K cycles.
Procedure
Inspect the latches for worn or damaged parts.
Open and close the latches and ensure they lock into place when closed.
Ensure the nylon wheel [2] turns freely on its bearing and that it aligns with its
locking
© Copyright 2009 GBC. All rights reserved.
[2]
[1]
Maintenance