Section 1

1.4.16 Bypass Paper Path Inspection and Cleaning

1-28
Maintenance Schedule
Clean every 750K cycles.
Replace every 4000K cycles. See Page 4-8.
Procedure
Inspect the Bypass panel [1], rollers [2], and entrance guide [3] for wear,
damage, and obstructions.
Inspect the rollers for wear patterns or groves. The surface should be rough
and even. Make sure the rollers are clean. Clean rollers with a soft cloth and
alcohol. See also "Idler Roller Inspection and Cleaning" on page 1-20 and
"Drive Roller Inspection and Cleaning" on page 1-24.
Raise the panel and ensure the magnet holds it in open [4]. Inspect the path
for obstructions. Clean as needed.
Close the panel and check that it is flat and that paper will pass under it.
Ensure the bypass diverter moves freely and returns to the bypass position.
[4]
[1]
Figure 1.16 Bypass Path Inspection. Shown With Bypass Panel Raised.