Section 1
1.4.16 Bypass Paper Path Inspection and Cleaning
1-28
Maintenance Schedule
Clean every 750K cycles.
Replace every 4000K cycles. See Page 4-8.
Procedure
•
Inspect the Bypass panel [1], rollers [2], and entrance guide [3] for wear,
damage, and obstructions.
•
Inspect the rollers for wear patterns or groves. The surface should be rough
and even. Make sure the rollers are clean. Clean rollers with a soft cloth and
alcohol. See also "Idler Roller Inspection and Cleaning" on page 1-20 and
"Drive Roller Inspection and Cleaning" on page 1-24.
•
Raise the panel and ensure the magnet holds it in open [4]. Inspect the path
for obstructions. Clean as needed.
•
Close the panel and check that it is flat and that paper will pass under it.
•
Ensure the bypass diverter moves freely and returns to the bypass position.
[4]
[1]
Figure 1.16 Bypass Path Inspection. Shown With Bypass Panel Raised.
© Copyright 2009 GBC. All rights reserved.
Advanced Punch Service Manual
[3]
[2]
[5]