Section 6
6.2 Adjustments and Feature Control General
Procedures
Item #
Description
GP1
Punch Counter
Adjusting counter for "Almost Full"
GP2
message
Punch "Almost Full" message ON/
GP3
OFF
Configuration recognition *related to
GP4
GP5
Configuration definition
GP5
*valid only if NVM 769-252 = 0
GP6
AdvancedPunch SW version display
6-4
Tools Mode).
2. Select the "Machine Status" button on the UI Control Panel (the right side hard
button immediately below the touch display).
3. Select the "Tools" tab.
4. Scroll to the bottom of the "Features" group.
5. Select the "Maintenance/Diagnostics" button on the UI screen.
6. Select the "NVM Read/Write" button.
7. Enter Chain-Link values as directed in
General Procedures"
Enter Chain Link #769-253
(Value range from 0 to 18,000,000 and is resettable)
Enter Chain Link #769-244
Adjust value from nominal = 30 (x100 punch cycles) to higher value if
message occurs before Punch Waste Container is near full or to a lower
value if "Full Waste Container" message occurs before "Near Full"
message is displayed.
Enter Chain Link # 769-250
0 = Detect
1 = Do not detect
Enter Chain Link # 769-252
0 = Disabled
1 = Enabled
Enter Chain Link # 769-226
0 = No AdvancedPunch
1 = A4 AdvancedPunch connected
2 = Letter AdvancedPunch connected
Enter Chain Link #769-251
© Copyright 2009 GBC. All rights reserved.
"Adjustments and Feature Control
on page 6-4 or as described in the NVM Settings List.
Adjustment Procedure