6.1.3 NVM Read/Write
Advanced Punch Service Manual
Procedure
1. Enter UI Diagnostic mode (see Entering and Exiting Maintenance/Diagnostic
Tools Mode).
2. Select the "Machine Status" button on the UI Control Panel (the right side hard
button immediately below the touch display).
3. Select the "Tools" tab.
4. Scroll to the bottom of the "Features" group.
5. Select the "Maintenance/Diagnostics" button on the UI screen.
6. Select the "IO Check" button.
7. Enter Chain-Link values as directed in the Component Control Tables, Section
6.3
and
6.4
8. From the IO Check menu, select Component Control. The following are
displayed:
•
Chain - Link dialog boxes (Refer to the appropriate table for the Chain-Link
code number)
• Table 1 GBC Inputs
• Table 2 GBC Outputs
•
Enter Number button
•
Show Current Status button
•
Cyclic Motion check box
•
Input / Output dialog box
•
Counter dialog box
•
Status dialog box
9. Enter the 6-digit chain-link (code) number for the component.
10. Press the Start button on the UI to energize the output component or to read
the status of the input component.
11. Select Cyclic Motion for the component to repeat the operation.
12. Input/Output column (component type), Status column (Operation status), and
Counter column (Operation Count) are displayed on the Component Control
screen.
13. Press the Stop button on the UI to halt the component operation.
Select Close to exit from Component Control.
Purpose
The purpose of this section is to provide a method to check and adjust certain
machine parameters stored and adjusted electronically. Adjustments to values are
retained after exiting this mode.
Procedure
1. Enter UI Diagnostics Mode (see Entering and Exiting Maintenance/Diagnostic