Specifications For Model Fc-795 Mfcs; Table 6-19. Specifications For Fc-795 Series Mfcs - Advanced Energy FC-77 Series User Manual

Mass flow controllers
Table of Contents

Advertisement

®
Advanced Energy

Specifications for Model FC-795 MFCs

The following table lists specifications for the FC-795 MFCs.

Table 6-19. Specifications for FC-795 series MFCs

Specification
Full-scale range (N
equivalent)
2
Valve type
Response time
Note 1
Accuracy
Linearity
Repeatability
External leak rate
Flow rate control range
Operating pressure
range
Note 2
Proof pressure
Operating temperature
Flow rate setting and output signal
Supply power
Power consumption
Gas-wetted surface material
Standard fitting
Mounting position
Weight
Options
Note 1—Accuracy ensures that the calibration gas equivalent flow is ±1% of full scale when 22 ± 3ºC in
temperature is obtained for the primary reference in the specified operating pressure range. If the service
gas and calibration gas are the same, the measured gas is ensured to be ±1% of full scale in the specified
operating pressure range as to our primary reference.
Note 2—The proof pressure specification does not ensure operation or accuracy.
6-20
Normally open
In
Out
Current output (0 mA to 2.5 mA), error detection function,
Specifications and Reference Information
FC-795
10 sccm to 5000 sccm
Maximum ±2% of full scale, within 1 s
Maximum ±1% of full scale
Maximum ±0.5% of full scale
Maximum at ±0.2% of full scale
-11
Maximum 1 x 10
[Pa*m
2% to 100%
49 to 275 kPa(G); 7 to 40 psi(G)
Atmosphere to vacuum 0 kPa(G), 0 kPa(A)
981 kPa(G); 142 psi(G)
5ºC to 45ºC (41ºF to 113ºF)
0 VDC to 5.0 VDC
Minimum +15 VDC ±2% 25 mA
Minimum -15 VDC ±2% 180 mA
Maximum 3.1 W
SUS316, SUS316L, PCTFE
Equivalent to 1/4" VCR
Any direction
0.9 kg (2.0 lb)
TC surface treatment
FC-795C
Normally closed
3
/sec(He)]
5700512-C

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fc-78 seriesFc-79 series

Table of Contents