Card Edge Purge Function Signals; Figure 4-5. Card Edge Purge Function Signals; Figure 4-6. Card Edge Normally Open Internal Circuitry For Purge Function - Advanced Energy FC-77 Series User Manual

Mass flow controllers
Table of Contents

Advertisement

Series FC-77X / 77XX, Series FC-78X / 78XX, and Series FC-79X MFCs

CARD EDGE PURGE FUNCTION SIGNALS

For the card edge connector, MFCs with normally open and normally closed valves
require inverse connections. Be sure to connect the signal properly. (To check whether
an MFC is normally closed or normally open, see
"Model Numbers for this Manual"
on page
1-1.)
Figure 4-5
shows the connections.
Figure 4-6
and
Figure 4-7
show the
internal circuitry for normally open and normally closed MFCs, respectively.
To disengage this function, disconnect the MFC terminal.

Figure 4-5. Card edge purge function signals

Figure 4-6. Card edge normally open internal circuitry for purge function

5700512-C
I/O Connections and Communication
4-9