Specifications For Model Fc-771 Mfcs; Table 6-2. Specifications For Fc-771 Series Mfcs - Advanced Energy FC-77 Series User Manual

Mass flow controllers
Table of Contents

Advertisement

Specifications for Model FC-771 MFCs

The following table lists specifications for the FC-771 MFCs.

Table 6-2. Specifications for FC-771 series MFCs

Specification
Full-scale range (N
equivalent)
2
Valve type
Response time
Note 1
Accuracy
Linearity
Repeatability
External leak rate
Flow rate control range
Operating pressure range
Note 2
Proof pressure
Operating temperature
Flow rate setting and output signal
Supply power
Power consumption
Gas-wetted surface material
Standard fitting
Mounting position
Weight
Options
Standard equipment
Note 1—Accuracy ensures that the calibration gas equivalent flow is ±1% of full scale when 22 ± 3ºC in
temperature is obtained for the primary reference in the specified operating pressure range. If the service
gas and calibration gas are the same, the measured gas is ensured to be ±1% of full scale in the specified
operating pressure range as to our primary reference.
Note 2—The proof pressure specification does not ensure operation or accuracy.
5700512-C
Series FC-77X / 77XX, Series FC-78X / 78XX, and Series FC-79X MFCs
FC-771A
6 slm to 20 slm
Normally open
Maximum ±2% of full scale, within 2 seconds
Under 20 slm, maximum ±1% of full scale (over 20 slm,
Under 20 slm, maximum ±0.5% of full scale (over 20 slm,
at ≥20 slm 98 to 275 kPa(D); 14 to 40 psi(D)
SUS316, SUS316L, KM-45, Viton, or Chloroprene rubber
1/4" VCR, 1/4" SW, 1/4" VCO, 3/8" VCR, 3/8" SW, 3/8" VCO
Current output (0 mA to 2.5 mA), 1/4" MCG fitting
Specifications and Reference Information
maximum, ±2% of full scale)
maximum, ±1% of full scale)
Maximum at ±0.2% of full scale
-7
3
Maximum 1 x 10
[Pa*m
2% to 100%
69 to 275 kPa(D); 10 to 40 psi(D)
981 kPa(G); 142 psi(G)
5ºC to 45ºC (41ºF to 113ºF)
0 VDC to 5.0 VDC
Minimum +15 VDC ±2% 25 mA,
Minimum -15 VDC ±2% 180 mA
Maximum 3.1 W
Any direction
0.9 kg (2.0 lb)
Error detection function
FC-771AC
6 slm to 50 slm
Normally closed
/sec(He)]
6-3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fc-78 seriesFc-79 series