Specifications For Model Fc-785Y-B Mfcs; Table 6-13. Specifications For Fc-785Y-B Series Mfcs - Advanced Energy FC-77 Series User Manual

Mass flow controllers
Table of Contents

Advertisement

®
Advanced Energy

Specifications for Model FC-785Y-B MFCs

The following table lists specifications for the FC-785Y-B MFCs.

Table 6-13. Specifications for FC-785Y-B series MFCs

Specification
Full-scale range (N
equivalent)
2
Valve type
Response time
Note 1
Accuracy
Linearity
Repeatability
External leak rate
Flow rate control range
Operating pressure range
Note 2
Proof pressure
Operating temperature
Flow rate setting and output signal
Supply power
Power consumption
Gas-wetted surface material
Mounting position
Weight
Options
Note 1—Accuracy ensures that the calibration gas equivalent flow is ±1% of full scale when 22 ± 3ºC
in temperature is obtained for the primary reference in the specified operating pressure range. If the ser-
vice gas and calibration gas are the same, the measured gas is ensured to be ±1% of full scale in the
specified operating pressure range as to our primary reference.
Note 2—The proof pressure specification does not ensure operation or accuracy.
6-14
FC-785Y-B
Normally open
Maximum ±2% of full scale, within 1 s
Maximum at ±0.2% of full scale
Maximum 1 x 10
49 to 275 kPa(D); 7 to 40 psi(D)
Minimum +15 VDC ±2% 25 mA
Minimum -15 VDC ±2% 180 mA
SUS316, SUS316L, PTFE, Ni, KM-45
Current output (0 mA to 2.5 mA), error detection, TC surface
Specifications and Reference Information
FC-785CY-B
10 sccm to 5000 sccm
Normally closed
Maximum ±1% of full scale
Maximum ±0.5% of full scale
-11
3
[Pa*m
/sec(He)]
2% to 100%
981 kPa(G); 142 psi(G)
5ºC to 45ºC (41ºF to 113ºF)
0 VDC to 5.0 VDC
Maximum 3.1 W
Any direction
1.3 kg (2.9 lb)
treatment
5700512-C

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fc-78 seriesFc-79 series

Table of Contents