CR Headphone assignments automatically switch to the Program 4 bus, and the bus
assignment keys for channels assigned to Program 4 flash.
Flexible: Allows activation of Flexible Record Mode, with custom Monitor, Headphone
•
and Meter options set in the "Flexible Record Mode Options" section that follows.
GPIO Channel For Recorder Control
Enter the GPIO channel number used to trigger your dedicated recording device.
•
This option should typically be programmed with the same logic channel number
for all Show Profiles.
Flexible Record Mode Options Section
When "Flexible" is chosen as the Record Mode Activation option, the following options are
active.
NOTE: The options below allow you to customize the Monitor, Headphone and Meter settings
that are auto- matically selected when you ENTER Record Mode.
CR Monitor Source
Retain: Does not change the Monitor feed; keeps the Monitor selection the board
•
operator was using prior to entering Record Mode.
Program 1 – 4, Record, Phone, Auxiliary A – D, External 1 – 2: Changes the
•
Monitor feed to the selected bus or Monitor channel when Record Mode is
engaged.
Recall: Re-loads the Monitor selection that was manually selected by the board operator
•
the last time
Record Mode was active.
Studio Monitor Source
Same options as described in "CR Monitor Source" above, but for the Studio Monitor
•
feed.
CR Headphone Source
Same options as described in "CR Monitor Source" above, but for the Control Room
•
Headphone feed.