9.2.4.7 Inspection Criteria

xVue Touch System
Component Description
KCP 100EXP Control
A general visual inspection of the KCP
Panel
100EXP Control Panel, installation and the
associated wiring must be performed
during each annual inspection. Visually
check wiring for general condition, routing,
chafing, bonding straps and/or wires and
integrity of clamping and stand-offs.
Visually check the mechanical installation
for condition, including checking the unit
and all mounting brackets for security.
Loose and chafing brackets will increase the
resistance between parts. Check for signs
that the units have not been tampered with
or removed. Inspect and verify the bonding
straps or ground wires are in good
condition, and are not loose or chafing.
Connection points to the units and to the
airframe must be inspected for evidence of
corrosion.
If any of these indications are present, an
electrical bonding test must be performed.
KTP 73 Outside Air
A general visual inspection of the KTP 73
Temperature Probe
Outside Air Temperature Probe and the
associated wiring must be performed
during each annual inspection. Visually
check wiring for general condition, routing,
chafing, bonding straps and/or wires and
integrity of clamping and stand-offs.
Visually check the mechanical installation
for condition, including checking the unit
and all mounting brackets for security.
Loose and chafing brackets will increase the
resistance between parts. Check for signs
that the units have not been tampered with
or removed. Inspect and verify the bonding
straps or ground wires are in good
condition, and are not loose or chafing.
Connection points to the units and to the
airframe must be inspected for evidence of
corrosion.
If any of these indications are present, an
electrical bonding test must be performed.
89000109-002
Rev 2
© Honeywell International Inc. Do not copy without express permission of Honeywell.
For Use in Non-Certified Aircraft

Table 9-1 ICA Inspection Criteria

Inspection Requirement
Recommended Minimum
Completed
Inspection Interval
12 months
12 months
xVue Touch Installation Manual
Page 9-4

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the XVUE TOUCH and is the answer not in the manual?

This manual is also suitable for:

Ksd 100expKg 71expKmg 7010Md32Ktp 73

Table of Contents