Network No.

Set the network number of the FX5-CCLGN-MS.
Item
Network No.
Precautions
Set a network number that does not duplicate any other network numbers.
When a network number is duplicated in the same system, an error will occur in the CPU module.
In particular, when using an Ethernet-equipped module (CPU module) at default, the IP address is 192.168.3.250 and the
network number is the third octet of the IP address, thus 3. Because setting the network number of the FX5-CCLGN-MS to 3
causes duplication, set another network number.

Parameter setting method

Set "Basic Settings" and "Application Settings" items using the engineering tool or in program.
Item
Setting Method of Basic/
Application Settings
Station number/IP address setting of a local station
The station number/IP address of a local station can be also set using the G(P).UINI instruction. This allows project data items
other than the station number/IP address to be shared. ( MELSEC iQ-F FX5 Programming Manual (Instructions, Standard
Functions/Function Blocks))
The procedure for setting the station number of a local station is as follows.
1.
Set "Station No./IP Address Setting Method" under "Station No./IP Address Setting" in "Required Settings" to "Program".
2.
Set "Setting Method of Basic/Application Settings" under "Parameter Setting Method" in "Required Settings" to
"Parameter Editor".
3.
Set the station number using the G(P).UINI instruction.
7 PARAMETER SETTINGS
90
7.2 Required Settings
Description
Set the network number of the FX5-CCLGN-MS.
Description
Select this item to set the parameter using the engineering tool.
The following are advantages.
• All parameters can be easily set in the window without creating a program for setting.
• Data can be automatically transferred from the link special relay (SB), link special register
(SW), and link devices of the FX5-CCLGN-MS to the devices of the FX5 CPU module.
Setting range
1 to 239
(Default: 1)
Setting range
Parameter Editor (fixed)