6.
Set the network configuration as follows. (Set the IP address for each station.)
[Navigation window]  [Parameter]  [Module Information]  [FX5-CCLGN-MS]  [Basic Settings]  [Network
Configuration Settings]
7.
Click the [Close with Reflecting the Setting] button to close the "CC-Link IE TSN Configuration" window.
8.
Set the refresh settings as follows.
[Navigation window]  [Parameter]  [Module Information]  [FX5-CCLGN-MS]  [Basic Settings]  [Refresh
Settings]
9.
In "Communication Mode" under "Application Settings", set "Unicast" or "Multicast".
[Navigation window]  [Parameter]  [Module Information]  [FX5-CCLGN-MS]  [Application Settings] 
[Communication Mode]
10.
Click the [Apply] button.
11.
Write the set parameters to the FX5 CPU module on the master station. Then, reset the FX5 CPU module or power off
and on the system.
[Online]  [Write to PLC]
In this example, default values are used for parameters that are not shown above. For the parameters, refer to
the following.
Page 89 PARAMETER SETTINGS
9.2 Communication Example between the Master Station and Local station
9 PROGRAMMING
115