Mitsubishi Electric MELSEC iQ-F FX5 Series User Manual page 103

Cc-link ie tsn
Hide thumbs Also See for MELSEC iQ-F FX5 Series:
Table of Contents

Advertisement

Simple
Detailed
Description
display
display
RWw Setting
Assign RWw/RWr points in increments of 4. ( Page 27 Communications
using RX, RY, RWr, and RWw)
RWr Setting
Modules with settings provided by profile are automatically set from selected
models. (Excluding modules with a number of points that is not fixed)
Parameter Automatic Setting
Set whether to set the parameters of each slave station automatically.
This cannot be set for extension modules. However, the parameter
automatic setting of extension modules is interlocked with the settings of the
connected main module.
IP Address
Set the IP address of a station that performs cyclic transmission.
Subnet Mask
Set a subnet mask to identify a network address.
Set the same value for the master station and slave station. Even if a slave
station has a different subnet mask from the master station, it does not result
in an input error.
If 255.255.255.255 is set, leave it empty.
Default Gateway
Set the default gateway address to connect to the external network.
Reserved/Error Invalid Station
Set the slave station as a reserved station or error invalid station.
• No Setting: The slave station is connected to the network.
• Reserved Station: The slave station is reserved for future expansion. By
using a reserved station, link device assignment will not change even if the
slave station is added (reservation is canceled). Therefore, modification of
the program is not required. Physical connection of the slave station on the
network is not required.
• Error Invalid Station: Even if a slave station is disconnected during data
link, the master station will not detect the slave station as a faulty station.
Communication Period Setting
When multiple communication cycles are set, set the cycle of each slave
station. ( Page 40 Communication cycle coexistence)
Station Information
■Alias
Enter the name of a device if required.
The name entered is displayed in "Network Status" of the "CC-Link IE TSN/
CC-Link IE Field Diagnostics" window.
For the extension module of the remote station, the name is not displayed in
the "CC-Link IE TSN/CC-Link IE Field Diagnostics" window, even if entered.
■Comment
Information entered in "Comment1" on the "Properties" window displayed by
right-clicking the module in the list of stations or the network map is
displayed.
■Station-specific mode setting
Set the station-specific mode of the slave station. (Only when the slave
station supports the station-specific mode)
Because a portion of the setting items are not displayed in simple display, when there are deficiencies in
setting items that are not displayed, the "Output" window may display a warning or error by selecting [Close
with Reflecting the Setting].
If a warning is displayed, switch to detailed display and correct the items.
Setting range
• Number of points: 4 to 4096
• Start: 0H to FFCH
• End: 3H to FFFH
(Default: Varies depending on the set module)
• Check: Distribute parameters
• Do Not check: Do not distribute parameters
(Default: Do Not check)
0.0.0.1 to 223.255.255.254
(Default: The first to third octets have the
same values as the master station, the fourth
octet has a serial number from 1 to 254)
• 0.0.0.1 to 255.255.255.255
• Empty
(Default: The same value if there is a master
station)
• 0.0.0.1 to 223.255.255.254
• Empty
(Default: empty)
• No Setting
• Reserved Station
• Error Invalid Station
(Default: No setting, master station is fixed as
empty)
• Basic Period
• Normal-Speed
• Low-Speed
(Default: Basic cycle, master station is fixed
as empty)
Up to 32 one-byte characters (one-byte or
two-byte)
(Default: empty)
Up to 32 one-byte characters (one-byte or
two-byte)
(Default: empty)
The setting varies depending on the set
module.
7 PARAMETER SETTINGS
7.5 "CC-Link IE TSN Configuration" Window
7
101