8
DEDICATED INSTRUCTION
This chapter describes the transmission ranges and dedicated instructions that can be used in the FX5-CCLGN-MS.
For details on dedicated instructions, refer to the following.
 MELSEC iQ-F FX5 Programming Manual (Instructions, Standard Functions/Function Blocks)
Link dedicated instructions
The following table lists the instructions used for transient transmission to or from programmable controllers on other stations.
■Instruction list
Instruction
GP.READ
GP.SREAD
GP.WRITE
GP.SWRITE
GP.SEND
GP.RECV
■Transient transmission ranges
In a single network system, communication with all stations on the network is possible.
Other dedicated instructions
Set the parameter in the FX5-CCLGN-MS.
■Instruction list
Instruction
G(P).UINI
Description
Reads the data from devices in the programmable controller of another station.
Reads the data from devices in the programmable controller of another station. For the GP.SREAD instruction,
when the reading of the data is completed, another station's devices are turned on. Other stations can
recognize that the data was read by GP.SREAD.
Writes the data to devices in the programmable controller of another station.
Writes the data to devices in the programmable controller of another station. For the GP.SWRITE instruction,
when the writing of the data is completed, another station's devices are turned on. Other stations can
recognize that the data was written by GP.SWRITE.
Sends data to the programmable controller of another station.
Reads the data received from the programmable controller of another station.
Description
Sets the station number and IP address in the FX5-CCLGN-MS.
8 DEDICATED INSTRUCTION
8
107