Mitsubishi Electric MELSEC iQ-F FX5 Series User Manual page 211

Cc-link ie tsn
Hide thumbs Also See for MELSEC iQ-F FX5 Series:
Table of Contents

Advertisement

No.
Name
SW0073
Cyclic transmission time
(calculation value)
SW0074
PORT1 cable disconnection
detection count
SW0075
PORT1 receive error
detection count
SW0076
PORT1 total number of
received data (lower 1 word)
SW0077
PORT1 total number of
received data (upper 1 word)
SW0078
Transient transmission time
(calculation value)
SW007C
PORT2 cable disconnection
detection count
SW007D
PORT2 receive error
detection count
SW007E
PORT2 total number of
received data (lower 1 word)
SW007F
PORT2 total number of
received data (upper 1 word)
SW00B0
Data link status of each
to
station
SW00B7
SW00C0
Reserved station setting
to
status
SW00C7
Description
Stores the cyclic transmission time calculated by the number of
slave stations and the number of points that are set in "Network
Configuration Settings" under "Basic Settings". (Unit: s)
Stores the cumulative count that was detected for cable
disconnections at the P1 side.
When 'Clear communication error count' (SB0006) is turned on, the
stored count is cleared.
When FFFFH (maximum value 65535) is counted, the value returns
to 0 and the module continues to count.
Stores the cumulative count that error data was received at the P1
side.
The count stores only error data that is not transmitted to all stations.
When 'Clear communication error count' (SB0006) is turned on, the
stored count is cleared.
When FFFFH (maximum value 65535) is counted, counting stops.
Stores the cumulative count that data was received at the P1 side.
When 'Clear communication error count' (SB0006) is turned on, the
stored count is cleared.
When FFFFFFFFH (maximum value 4294967295) is counted,
counting stops.
Stores the transient transmission time calculated by the number of
slave stations and the number of points that are set in "Network
Configuration Settings" under "Basic Settings". (Unit: s)
Stores the cumulative count that was detected for cable
disconnections at the P2 side.
When 'Clear communication error count' (SB0006) is turned on, the
stored count is cleared.
When FFFFH (maximum value 65535) is counted, the value returns
to 0 and the module continues to count.
Stores the cumulative count that error data was received at the P2
side.
The count stores only error data that is not transmitted to all stations.
When 'Clear communication error count' (SB0006) is turned on, the
stored count is cleared.
When FFFFH (maximum value 65535) is counted, counting stops.
Stores the cumulative count that data was received at the P2 side.
When 'Clear communication error count' (SB0006) is turned on, the
stored count is cleared.
When FFFFFFFFH (maximum value 4294967295) is counted,
counting stops.
Stores the data link status of each station.
0: Data link normally operating station
1: Data link faulty station
• If multiple stations change from faulty to normal, because they are
reconnected to the network one by one per cycle, the time until
the status changes to "0: Data link normally operating station"
may vary by several seconds.
• If no response is received for several cycles, the station is
determined to be a data link faulty station.
Since a local station cannot obtain the station information of the
authentication Class A remote station when communicating in
multicast mode, "0: Data link normally operating station" is reflected
to the remote station.
(Conditions)
• Stations that surpass the maximum station number are ignored.
(Also used in the CLPA conformance test.)
Stores the reserved station setting status of each station.
0: Station other than a reserved station
1: Reserved station
(Conditions)
• Stations that surpass the maximum station number are ignored.
(Also used in the CLPA conformance test.)
Availability
Master
Local station
station
Unicast
mode
Appendix 5 List of Link Special Register (SW)
Multicast
mode
A
*1
*1
APPX
209