Station Type

Set the station type of the Simple Motion module.
Item
Description
Station Type
Use the Simple Motion module as a master station.
One master station can be set in a network.

Network No.

Set the network No. of the Simple Motion module.
Item
Description
Network No.
Set the network No. of the Simple Motion module.

Station No.

Set the station No. of the Simple Motion module.
Item
Description
Setting Method
Set the station No. in parameter editor.
Station No.
The station No. of the master station is fixed to "0".

Parameter Setting Method

Set "Basic Settings" and "Application Settings" items of the Simple Motion module in parameter editor.
Item
Description
Setting Method of Basic/
Set the parameter using the engineering tool. The following are advantages.
Application Settings
• Parameters can be easily set in the window without creating a program for setting.
• The data will be automatically transferred between the devices of the CPU module and
the link special relay (SB), link special register (SW), and link devices of the Simple
Motion module, or between the module label of the CPU module and the link special
relay (SB) and link special register (SW) of the Simple Motion module.
Setting range
Setting range
1 to 239
(Default: 1)
Setting range
Setting range
2 PARAMETER SETTINGS
2.2 Required Settings
2