When the parameters of required settings are not set, the module operates as a local station of network No.1
and station No.1.
However, baton pass and data link are not performed.

Station Type

Set the station type of the master/local module.
Item
Station Type

Network No.

Set the network number of the master/local module.
Item
Network No.

Station No.

Set the station number of the master/local module.
Item
*1
Setting Method
Station No.
*1 When "RJ71GF11-T2 (MR)", "RJ71GF11-T2 (SR)", or "RJ71GF11-T2 (LR)" is selected for the module model name, the setting is fixed to
"Parameter Editor".
*2 When "RJ71GF11-T2 (SR)" is selected for the module model name, the setting range is from 1 to 119.
2 PARAMETER SETTINGS
126
2.2 Required Settings
Description
Select whether to use the master/local module as a master station, local station, or
submaster station.
One master station and one submaster station can be set in a network.
Description
Set the network number of the master/local module.
Description
Select whether to set the station number in parameter editor or in program (UINI
instruction). This item can be set only for a local station.
When selecting "Program", use the UINI instruction to set the number. ( MELSEC iQ-
R Programming Manual (Instructions, Standard Functions/Function Blocks))
Set the station number of the master/local module. Set a station number different from
those used in the same network. The station number of the master station is fixed to "0".
To set the station number of a local station in this setting, set "Setting Method" to
"Parameter Editor".
When "Submaster Station" is selected for "Station Type" of "Required Settings" and the
following is set, the setting value set in "Network Configuration Settings" of "Basic
Settings" is displayed.
• When "Operate with Parameter of Host Station" is selected in "Submaster Parameters"
in "Basic Settings"
Setting range
• Master Station
• Local Station
• Submaster Station
• Master Station (Redundant Line)
(Default: Station type set in the "Add
New Module" window.)
Setting range
1 to 239
(Default: 1)
Setting range
• Parameter Editor
• Program
(Default: Parameter Editor)
• Master Station: Fixed to "0"
*2
• Local Station: 1 to 120
• Submaster Station: 1 to 120
(Default: 1)