Mitsubishi Electric MELSEC iQ-F FX5 Series User Manual page 212

Cc-link ie tsn
Hide thumbs Also See for MELSEC iQ-F FX5 Series:
Table of Contents

Advertisement

No.
Name
SW00C8
Parameter setting status
to
SW00CF
SW00D0
Error invalid station setting
to
status
SW00D7
SW00E8
Station type match status
to
SW00EF
SW00F0
CPU operating status of each
to
station
SW00F7
SW0100
CPU moderate/major error
to
status of each station
SW0107
SW0110
CPU minor error status of
to
each station
SW0117
SW0160
Execution result of slave
to
station parameter automatic
SW0167
setting function
SW0194
Detailed execution result of
slave station parameter
automatic setting
SW0198
Link dedicated instructions
processing result CH3
APPX
210
Appendix 5 List of Link Special Register (SW)
Description
Stores the status of parameter settings.
0: No parameter setting
1: Parameter set
(Conditions)
• Stations that surpass the maximum station number are ignored.
Stores the error invalid station setting status of each station.
0: Station other than an error invalid station
1: Error invalid station
(Conditions)
• Stations that surpass the maximum station number are ignored.
Shows the match status of the parameters with the station types.
(This is available only for the number of connected modules.)
0: Station type matched
1: Station type mismatch
Stores the CPU operating status of each station.
0: RUN or PAUSE state
1: STOP state or moderate/major error
(Conditions)
• Reserved stations and stations that surpass the maximum station
number are ignored.
• Since a local station cannot obtain the station information of the
authentication Class A remote station when communicating in
multicast mode, the authentication Class A remote station turns
into RUN or PAUSE state.
Stores the moderate/major error occurrence status of each station.
0: No moderate/major error
1: Moderate/major error occurring
(Conditions)
• If an error occurs, data prior to error is held.
• Reserved stations and stations that surpass the maximum station
number are ignored.
• Since a local station cannot obtain the station information of the
authentication Class A remote station when communicating in
multicast mode, "0: No moderate/major error" is reflected to the
remote station.
Stores the minor error occurrence status of each station.
0: Normal, or a moderate or serious error occurring
1: Minor error occurring
(Conditions)
• Reserved stations and stations that surpass the maximum station
number are ignored.
• Since a local station cannot obtain the station information of the
authentication Class A remote station when communicating in
multicast mode, "0: Normal or moderate/major error occurring" is
reflected to the remote station.
When the slave station parameter automatic setting is completed
with an error, the bit of the target station is turned on.
On: Completed with an error
Off: Completed successfully
When the setting is completed with an error, the error code is stored
in 'Detailed execution result of slave station parameter automatic
setting' (SW0194).
When completed with an error caused by the master station, the bit
is not turned on.
When the slave station parameter automatic setting is completed
with an error, the error code is stored.
When completed with an error caused by the slave station, the bit of
the target station of 'Execution result of slave station parameter
automatic setting function' (SW0160 to SW0167) is turned on.
Stores the processing results of the link dedicated instruction that
used channel 3 of the own station.
0: Completed successfully
1 or greater: Completed with an error (Error code is stored.)
Availability
Master
Local station
station
Unicast
Multicast
mode
mode
*1
*1
*1
*1
*1
*1