Target Module Information
Method selection
Parameter
[Clear All "Read Value"] button
Information
[Clear All "Write Value/Setting
Value"] button
Processing option
[Import] button
[Export] button
Procedure for clearing a saved parameter
When returning the saved parameters of a not-required slave station to the not-set status, perform the following procedure.
1.
If the saved parameters are to be saved, output them in a CSV file using the [Export] button.
2.
Delete not-required slave stations from the list of stations.
3.
Select the same module as the deleted slave station in "Module List", and drag it to the list of stations or the network
map.
Conditions for clearing a saved parameter
Saved parameters of a slave station can be cleared under the following conditions.
When saved parameters are cleared, execute "Parameter auto-setting" or "Parameter read" in the "Parameter of Slave
Station" window and read the parameters of the slave station.
Item
Operation
"CC-Link IE TSN
Open the "CC-Link IE TSN Configuration" window.
Configuration" window
Reflect setting and close the window.
Execute detection of connected/disconnected devices.
Change the function version in the "Properties" window.
"Parameter of Slave
Open the "Parameter of Slave Station" window.
Station" window
Module Parameter
Manually delete "Network Configuration Settings" to apply.
Change the "Setting Method of Basic/Application Settings"
under "Parameter Setting Method" in "Required Settings"
from "Parameter Editor" to "Program".
Change "Station Type" or set parameters that do not exist.
System Parameter
Divert system parameters from another project.
Module Configuration
Delete a module and check.
Navigation window
Delete a module.
Read from PLC
Read module parameters that have a different network
configuration and the same Intelligent module No.
Navigation window
Import the data of a simple motion module to take network
settings.
MELSOFT Navigator
Reflect the parameter.
Description
Information for the selected slave stations is displayed.
Select processing to be executed for selected slave stations.
• Parameter auto-setting: Automatically set contents of "Write Value/Setting Value" to the slave
station. ( Page 63 Slave station parameter automatic setting)
• Parameter read: Read parameters from the selected slave station.
• Parameter write: Write parameters to the selected slave station.
Click to clear all setting details that were read using "Parameter read".
Click to clear all setting details that are written using "Parameter write".
When there are options for processing selected by "Method Selection", setting items are displayed.
Read contents of parameter processing created in a CSV file.
Output contents of parameter processing set in this window to a CSV file.
Description
When there is not a slave station with the station number that
matches saved parameters in the "CC-Link IE TSN Configuration"
window, saved parameters of the relevant slave station are
skipped.
Skipped parameters of the slave station are cleared.
Saved parameters of a slave station that is not in the actual system
configuration are cleared.
All saved parameters are cleared.
When the "Properties" window is closed, saved parameters are
cleared.
Saved parameters that mismatch the relevant slave station are
skipped.
Clicking the [Close with Reflecting the Setting] button in the above
state clears the skipped saved parameters.
Parameters of "Network Configuration Settings" return to default.
Parameters of the slave station are not diverted.
Parameters are deleted together with the module.
Parameters are overwritten.
Saved parameters are cleared.