Mitsubishi Electric MELSEC iQ-F FX5 Series User Manual page 203

Cc-link ie tsn
Hide thumbs Also See for MELSEC iQ-F FX5 Series:
Table of Contents

Advertisement

List of link special relay (SB)
The following table lists the link special relay areas (SB) when they are assigned from SB0000 to SB0FFF.
Do not turn on or off areas whose numbers are not in the following list. Doing so may cause malfunction of the
programmable controller system.
No.
Name
SB0006
Clear communication error
count
SB0014
Cyclic data receive status
clear
SB0030
RECV execution request flag
CH1
SB0031
RECV execution request flag
CH2
SB0032
RECV execution request flag
CH3
SB0033
RECV execution request flag
CH4
SB0034
RECV execution request flag
CH5
SB0035
RECV execution request flag
CH6
SB0036
RECV execution request flag
CH7
SB0037
RECV execution request flag
CH8
SB0040
Network type of own station
SB0043
Module operation mode of
own station
SB0044
Station setting 1 of own
station
SB0045
Station setting 2 of own
station
SB0046
Station number setting status
of own station
Description
Clears the link special register areas related to communication
errors (SW0074 to SW0077, SW007C to SW007F) to 0.
Off: Clear not requested
On: Clear requested (valid while on)
Clears 'Cyclic data receive status' (SB0064).
While 'Cyclic data receive status clear' (SB0014) is on, the cyclic
data receive status does not turn on.
Off: Clear not requested
On: Clear requested (enabled while on)
Stores the data reception status of own station channel 1.
Off: No data received
On: Data received
Stores the data reception status of own station channel 2.
Off: No data received
On: Data received
Stores the data reception status of own station channel 3.
Off: No data received
On: Data received
Stores the data reception status of own station channel 4.
Off: No data received
On: Data received
Stores the data reception status of own station channel 5.
Off: No data received
On: Data received
Stores the data reception status of own station channel 6.
Off: No data received
On: Data received
Stores the data reception status of own station channel 7.
Off: No data received
On: Data received
Stores the data reception status of own station channel 8.
Off: No data received
On: Data received
Stores the network type of the own station.
ON: CC-Link IE TSN
Stores the module operation mode of the own station.
Off: Online mode
On: Other than online mode
Stores the station type of the own station.
Off: Slave station (other than the master station)
On: Master station
Stores the communication mode of the own station.
Off: Unicast mode
On: Multicast mode
Stores the station number setting status.
Off: Station number set
On: Station number not set (local station only)
If parameters are set using the engineering tool, this relay is always
off.
Availability
Master
Local station
station
Unicast
mode
Appendix 4 List of Link Special Relay (SB)
Multicast
mode
A
APPX
201