7. LW3 Programmers' Reference
7.18.6. Copy an EDID to User Memory
Command and Response
ç CALL·/EDID:copy(<source>:<destination>)
æ mO·/EDID:copy
Parameters
Parameter
Parameter description
<source>
Source EDID memory place
<destination>
The emulated EDID memory of the desired input port
Example
ç CALL /EDID:copy(F1:U2)
æ mO /EDID:copy
7.18.7. Deleting an EDID from User Memory
Command and Response
ç CALL·/EDID:delete(<user_edid>)
æ mO·/EDID:delete
Parameters
Parameter
Parameter description
<user_edid>
The emulated EDID memory of the desired input port.
Example
ç CALL /EDID:delete(U2)
æ mO /EDID:delete
MMX4x2 series – User's Manual
7.18.8. Resetting the Emulated EDIDs
Command and Response
Parameters
Values
Value description
F1-F120 Factory EDIDs
User EDIDs
U1-U14
Example
Dynamic EDIDs
D1-D2
U1-U14
User EDIDs
Values
Value description
User EDIDs
U1-U14
Applied firmware package: v1.5.0b8 | LDC software: v2.3.0b1
ç CALL·/EDID:reset()
æ mO·/EDID:reset
Parameter
Parameter description
<user_edid>
The emulated EDID memory of the desired input port.
ç CALL /EDID:reset()
æ mO /EDID:reset
Calling this method switches all emulated EDIDs to factory default one. See the table in the
List
section.
105
Values
Value description
User EDIDs
U1-U14
Factory EDID

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MMX4x2-HDMI and is the answer not in the manual?

This manual is also suitable for:

Mmx4x2-ht200Mmx4x2-hdmi-usb20-lMmx4x2 series

Table of Contents