HIKVISION EKI-K82T46 User Manual page 108

Table of Contents

Advertisement

4. Set the
VCA
detection type to
5. Check the Enable checkbox to enable this function.
6. Click
to configure the trigger channel, arming schedule, and linkage actions for the
detection
alarm.
7. Click the Rule Settings button to set the
1) Set the direction to A<->B, A->B, or A<-B.
A<->B: Only the arrow on the B side shows; an object going across the configured line in either
direction will be detected and trigger an alarm.
A->B: Only an object crossing the configured line from the A side to the B side will be detected.
B->A: Only an object crossing the configured line from the B side to the A side will be detected.
2) Click-and-drag the slider to set the detection sensitivity.
Sensitivity: Range [1−100]. The higher the value, the more easily the detection alarm can be
triggered.
3) Click OK to save the rule settings and go back to the
8. Click
and set two points in the preview window to draw a virtual line.
9. (Optional) Use the
Up to four rules can be configured.
NOTE:
NVR User Manual 061220NA
Line Crossing
line crossing detection
Figure 155, Set
Line Crossing Detection
to clear the existing virtual line and re-draw it.
Detection.
rules.
line crossing detection
settings interface.
Rules
line crossing
108