Barco STELLAR User And Service Manual page 138

Mpeg-2
Table of Contents

Advertisement

5
No.
Information
33
Power supply
failure
51
System
configuration
error
54
System event
16
Video output error Genlock ref.
126
ROSA messages
Name
Enabled
Severity
+15 V error
Off
Major
+3.3 V error Off
Major
+5.0 V error Off
Major
-15 V error
Off
Major
Alarm
On
Information Disable
queue lost
Configuratio
On
Information A
n error
Default lost
On
Information C
Product
On
Information B
check failed
SW options
On
Information B
lost
Download
Off
Information Disable
started
Off
Warning
input loss
Video
On
Major
decoding
error
Category
Explanation/Remedy
Disable
The supply rail is not within the legal
range. It may compromise the operation.
Disable
The supply rail is not within the legal
range. It may compromise the operation.
Disable
The supply rail is not within the legal
range. It may compromise the operation.
Disable
The supply rail is not within the legal
range. It may compromise the operation.
All messages from previous session(s) are
lost.
The detected configuration is different
from what has been defined. Revise your
module configuration.
The user-defined default settings are lost.
The decoder starts with factory defaults.
Change the settings, if necessary.
A module is found in a place where it's
not allowed. Remove the module.
The software options codes have to be re-
installed. Use the command SYStem :
OPTion : INSTall.
The decoder has entered download mode.
Download to a module has started.
Disable
There is no genlock reference. The video
output runs at nominal frame rate. Check
your genlock reference feed.
A
There is no valid video output due to
decoding errors. Check the source and the
condition of the input signal