Barco STELLAR User And Service Manual page 136

Mpeg-2
Table of Contents

Advertisement

5
No.
Information
7
Communication
port error
2
Contact closure
occurred
34
Device software
error
36
Hardware failure
37
Module
configuration
error
40
MPEG PSI error
124
ROSA messages
Name
Enabled
Severity
Communica
On
Information Disable
tion error
Close
On
Information Disable
Open
On
Information Disable
General
Off
Information Disable
software
error
RTK related
Off
Information Disable
SW error
Module
On
Information A
hardware
error
Module
On
Information B
selftest error
Misplaced
On
Major
module
Module is
On
Major
removed
Module is
On
Major
unknown
No module
On
Major
handler
Pig.
On
Major
misplaced or
missing
PCR
On
Major
accuracy
error
Program not
On
Warning
in PAT
Category
Explanation/Remedy
Check the terminal settings.
One of the contact closure contacts has
closed and thereby activated a macro.
Reload the ROSA windows to get the
actual settings from the decoder.
One of the contact closure contacts has
opened and thereby activated a macro.
Reload the ROSA windows to get the
actual settings from the decoder.
A software error has occurred. When
persistent, contact your local BARCO
sales office for further assistance.
A software error has occurred. When
persistent, contact your local BARCO
sales office for further assistance.
Replace the module in question.
The self-test has failed. Replace the
module in question.
B
A module was missing at power-up or a
known module was misplaced.
B
A module is missing. Replace the module
or make a new configuration.
B
The module is not known by the system
controller. The module stock number may
be lost or your system controller software
is too old to handle the module.
A
The stock number of the module is not
known to the system controller. Check the
stock number and slot position of the
module. Check if the firmware supports
the module.
B
The reference check of the piggy-back
module failed, indicating that the module
is either misplaced or missing.
A
The PLL cannot lock to the PCR values
due to inaccuracy (e.g. excessive jitter,
frequency error, etc.). Set the Video
Synchronization mode to "Free Running".
B
The selected program is not found in the
PAT. Check the source and select the
correct program.