N

Before you start

General precautions
Factory installed
Unpacking the S
14

Before you start

This chapter contains instructions for installing the S
must be read to ensure correct installation. When handling the S
take the following precautions:
• Use proper precautions against ESD.
• Do not change a blown fuse before the line plug is pulled out.
The line power input is protected with fuses in the supply connectors.
• When the S
TELLAR
through a distribution module or a bus bar being part of the rack.
• The wire size for the cable used to connect the S
module or bus bar must be minimum 2.0 mm
• The DC power supply must include a ≤15 A DC branch-protected UL-listed
fuse. This fuse must be placed in the negative wire in order to protect the rack
wiring and the power connector of the S
type of fuse in order to pass the in-rush current during power-up.
• If you use a floating DC power source, the positive terminal must be connected
to chassis and local earth ground to prevent building up of dangerous voltages.
The DC power supply input is floating with respect to chassis ground on the
S
.
TELLAR
The S
is customer-specific and is delivered with the modules which the cus-
TELLAR
tomer has specified. All the ordered options and modules are installed at the factory.
Note!
If, at a later date, you wish to add further options or modules you must
send the S
Note!
Under no circumstances should non-BARCO personnel attempt to
install modules in the S
When unpacking the S
TELLAR
rial for obvious signs of damage. Check the equipment against the delivery/packing
note. Retain the packing material as it is required for warranty shipments and for later
inspection by the carrier.
Note!
Should any item be damaged or any equipment be missing, notify the
carrier and your BARCO representative.
The S
is ready for installation when you have ensured that all the equipment
TELLAR
you ordered has been received and no damage has occurred. However, before you
apply power to the S
cautions in the section Preface.
is DC-supplied, you must connect it to the DC source
TELLAR
back to the factory and we will install them for you.
TELLAR
.
TELLAR
, examine the decoder, accessories, and packing mate-
TELLAR
we recommend that you read the section Safety and pre-
TELLAR
MPEG-2 decoder and
TELLAR
, you must
TELLAR
to the DC distribution
TELLAR
2
/14 AWG.
. We recommend a slow-blow