X13, Supply Blower Unit Hab01 - Bosch Rexroth IndraDrive HMV Project Planning Manual

Supply units and power sections
Table of Contents

Advertisement

Project Planning Manual | Rexroth IndraDrive
8.10

X13, Supply Blower Unit HAB01

Description
CAUTION
1
lines to control voltage supply
Fig.8-31:
Control voltage supply at X13
The input 0V is connected in conductive form with the housing po‐
tential. It is therefore impossible to use an insulation monitor at
+24V and 0V against housing.
Via this connection, the blower unit HAB01 of HMV01.1R‑W0120 and
HMS01.1N-W0350 devices is supplied with voltage (24V, 0V). The connection
is situated at the bottom of the device
Risk of damage by overheating!
Always operate HMV01.1R-W0120 and HMS01.1N-W0350 with the blower unit
HAB01.
Do not operate any other loads at connection X13.
Electric Drives
| Bosch Rexroth AG
and Controls
Functions and Electrical Connection Points
(see figure
below).