120/369
Bosch Rexroth AG | Electric Drives
Power Sections for Inverters - IndraDrive M
Description
output frequency range at
f
= 16 kHz
s
output frequency threshold to de‐
tect motor standstill
4)
maximum output current at
f
= 2 kHz
s
maximum output current at
f
= 4 kHz
s
maximum output current at
f
= 8 kHz
s
maximum output current at
f
= 12 kHz
s
maximum output current at
f
= 16 kHz
s
allowed continuous output current
at f
= 2 kHz
s
allowed continuous output current
at f
= 4 kHz
s
allowed continuous output current
at f
= 8 kHz
s
allowed continuous output current
at f
= 12 kHz
5)
s
allowed continuous output current
at f
= 16 kHz
6)
s
allowed continuous output current
at f
= 2 kHz; output frequency
s
f
< f
out
out_still
allowed continuous output current
at f
= 4 kHz; output frequency
s
f
< f
out
out_still
allowed continuous output current
at f
= 8 kHz; output frequency
s
f
< f
out
out_still
allowed continuous output current
at f
= 12 kHz; output frequency
s
f
< f
7)
out
out_still
and Controls
HMS01.1N-
Symbol
Unit
W0020
f
Hz
out_16k
f
Hz
out_still
I
A
out_max2
I
A
out_max4
I
A
out_max8
I
A
out_max12
I
A
out_max16
I
A
out_cont2
I
A
out_cont4
I
A
out_cont8
I
A
out_cont12
I
A
out_cont16
I
A
out_cont0Hz_
2
I
A
out_cont0Hz_
4
I
A
out_cont0Hz_
8
I
A
out_cont0Hz_
12
Rexroth IndraDrive | Project Planning Manual
HMS01.1N-
W0036
0...1600
2...4
-
20,0
36,0
20,0
36,0
16,0
31,0
11,0
24,0
-
12,1
21,3
8,3
15,0
5,0
9,5
2,7
6,0
-
8,1
14,2
5,5
10,0
3,3
6,4
HMS01.1N-
HMS01.1N-
W0054
W0070
54,0
70,7
54,0
70,7
45,0
65,0
35,0
51,0
35,0
42,4
20,0
24,1
12,0
14,4
7,5
9,3
23,4
28,3
13,4
16,1
8,2
9,6