Project Planning Manual | Rexroth IndraDrive
7.2.4
Technical Data HMV01.1E
Ambient and Operating Conditions
Description
Suitable for use on a circuit capable
of delivering not more than this
SCCR, symmetrical amperes (UL)
1)
rated input voltage, power (UL)
rated input current (UL)
3)
maximum output voltage (UL)
maximum output current (UL)
Description
listing according to UL standard
(UL)
UL files (UL)
listing according to CSA standard
(UL)
●
1 × connector X31, X32 and X33 each
●
1 × joint bar to connect the equipment grounding conductor to a neigh‐
boring device
●
1 × standard control panel each
●
1 × brochure with safety instructions (in 5 languages)
General Information
Conditions for transport and storage: see chapter
page
19.
Installation conditions: see chapter
This chapter contains:
●
limit values for use in the scope of C-UL
●
applied standards (CE conformity, UL listing)
UL Data
Ambient and operating conditions - UL ratings
Symbol
Unit
HMV01.1E-W0030
I
A rms
SCCR
U
V
2)
LN_nenn
I
A
L_cont
U
V
out
I
A
out_max
1)
600 V AC or less, use listed AC input line fuses or listed circuit breakers
2)
HMS, HMD, HLB, HLC, KCU: DC bus L+, L-; HMV, HCS: mains input
L1, L2, L3
3)
at PDC_cont
Fig.7-7:
HMV - Ambient and operating conditions - UL ratings
Information on Standards
Applied standards
Symbol
Unit
HMV01.1E-W0030
Fig.7-8:
HMV - Applied standards
Electric Drives
| Bosch Rexroth AG
and Controls
4.2 Transport and Storage,
4.3 Installation Conditions , page
HMV01.1E-W0075
42000
380...480
51,0
128,0
435...710 dc
69,0
173,0
HMV01.1E-W0075
UL 508 C
E 134201
Canadian National Standard(s) C22.2 No. 14-05
187/369
IndraDrive M Supply Units
19.
HMV01.1E-W0120
204,0
276,0
HMV01.1E-W0120