HAS02.1-014 at HMS01.1N-W0350

11.3.7

Shield Connection of the Motor Cable via Mains Filter

General Information

1.
Screw fixing device to equipment grounding conductor connection of drive
controller.
2.
Fix shield of cable with shielding plate to fixing device.
1
fixing device
2
shielding plate
3
clip
Fig.11-51:
HAS02.1-014 at bottom of drive controller HMS01.1N‑W0350
1. By means of supplied screws, fasten fixing device to front of blower unit.
2. Fix shielding plate to fixing device.
3. Fix shield of cable to shielding plate with appropriate clip.
There is a special shielding plate for shield connection of the motor cable via
the mains filter at the drive controller: