Has02.1-009 With Power Supply Cable And Mains Filter - Bosch Rexroth IndraDrive HMV Project Planning Manual

Supply units and power sections
Table of Contents

Advertisement

358/369
Bosch Rexroth AG | Electric Drives
Accessories

HAS02.1-009 With Power Supply Cable and Mains Filter

Mounting
and Controls
1
fixing device
2
shielding plate
3
clip
4
different possibilities of mounting the shielding plate, according to cable
routing
5
power supply cable
6
motor cable
Fig.11-54:
HAS02.1-009 at bottom of mains filter (rated current 146 A)
1.
By means of supplied screws, fasten fixing device to bottom of drive con‐
troller.
2.
Fix shielding plate to fixing device according to desired motor cable rout‐
ing.
3.
Fix shield of cable to shielding plate with appropriate clip.
The shield terminals must not be used to provide strain relief.
Rexroth IndraDrive | Project Planning Manual