Bosch Rexroth IndraDrive HMV Project Planning Manual page 218

Supply units and power sections
Table of Contents

Advertisement

208/369
Bosch Rexroth AG | Electric Drives
IndraDrive M Supply Units
Description
weight
device height (UL)
1)
device depth (UL)
2)
device width (UL)
3)
insulation resistance at DC 500 V
capacitance against housing
average sound pressure level (ac‐
curacy class 2) at P
4)
DC_cont
Description
ambient temperature range during
operation with nominal data
ambient temperature range during
operation with reduced nominal da‐
ta
derating of P
; P
; I
DC_cont
BD
out_cont
T
< T
< T
a_work
a
a_work_red
allowed mounting position
cooling type
volumetric capacity of forced cool‐
ing
power dissipation at continuous
current and continuous DC bus
power respectively (UL)
1)
and Controls
Device
HMV01.1R-W0018
HMV01.1R-W0045
HMV01.1R-W0065
HMV01.1R-W0120
Fig.7-32:
Dimensions
Dimensions, Mass, Insulation, Sound Pressure Level
Data for mass, dimensions, sound pressure level, insulation
HMV01.1R-
Symbol
Unit
m
kg
H
mm
T
mm
B
mm
R
MOhm
is
C
nF
Y
L
dB (A)
P
1) 2) 3)
housing dimension; see also related dimensional drawing
4)
according to DIN EN ISO 11205; comparative value at distance 1 m, out
of cabinet; HCS types with order code -L***: load-dependent
Fig.7-33:
HMV - Data for mass, dimensions, sound pressure level, insulation
Power Dissipation, Mounting Position, Cooling, Distances
Data for cooling and power dissipation
HMV01.1R-
Symbol
Unit
T
°C
a_work
T
°C
a_work_red
at
f
%/K
Ta
V
m
/h
3
P
W
Diss_cont
Rexroth IndraDrive | Project Planning Manual
L
[mm]
175
250
350
350
HMV01.1R-
W0018
W0045
13,50
20,00
440
262
175
250
tbd
tbd
tbd
HMV01.1R-
W0018
W0045
0...+40
0...55
2,0
G1
forced ventilation
tbd
290,00
680,00
L1
[mm]
125
200
300
300
HMV01.1R-
HMV01.1R-
W0065
W0120
31,00
34,50
350
80
HMV01.1R-
HMV01.1R-
W0065
W0120
1400,00
800,00
2000,00

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents