Mains Synchronization Hmv02 - Bosch Rexroth IndraDrive HMV Project Planning Manual

Supply units and power sections
Table of Contents

Advertisement

270/369
Bosch Rexroth AG | Electric Drives
Functions and Electrical Connection Points
8.11.3

Mains Synchronization HMV02

and Controls
1)
fusing of connection X14
2)
in-phase connection required
3)
mains choke
4)
mains filter
Fig.8-36:
Synchronizing voltage HMV01.1R
Install slow 5 A fuses in the supply line to connection X14.
Connect the connections X3 and X14 in phase:
X3.L1 in phase with X14.1
X3.L2 in phase with X14.2
X3.L3 in phase with X14.3
For mains synchronization, connect the output X14 of the HNS02 mains filter
to the input for mains voltage synchronization X14 of HMV02.1R.