Bosch Rexroth IndraDrive HMV Project Planning Manual page 271

Supply units and power sections
Table of Contents

Advertisement

Project Planning Manual | Rexroth IndraDrive
Coding of the Connectors
An external contact element is required, if motor holding brakes with
higher currents than the allowed current load are to be supplied at
X6.
At the HMD power sections with two inverter outputs, the outputs
have been coded, i.e. provided with a coding section. This avoids
accidentally interchanging the two cables.
Coding
X6.1: coding section at pin 4
X6.2: coding section at pin 1
For ready-made Rexroth motor power cables, you therefore have
to code the male connector at the motor power cable accordingly
for X6.1 and X6.2:
for connector X6.1: cut off plastic pin 4 at connector
for connector X6.2: cut off plastic pin 1 at connector
Fig.8-25:
Coding of X6.1 and X6.2