Project Planning Manual | Rexroth IndraDrive
HAS02.1-003 at HMS01.1N-W0210
Mounting
1
fixing device
2
shielding plate
3
clip
4
different possibilities of mounting the shielding plate, according to motor
cable routing
Fig.11-46:
HAS02.1-003 at bottom of drive controller HMS01.1N‑W0210
1.
By means of supplied screws, fasten fixing device to bottom of drive con‐
troller.
2.
Fix shielding plate to fixing device according to desired motor cable rout‐
ing.
3.
Fix shield of cable to shielding plate with appropriate clip.
Electric Drives
| Bosch Rexroth AG
and Controls
351/369
Accessories