Scope Of Supply; Technical Data; Ambient And Operating Conditions - Bosch Rexroth IndraDrive HMV Project Planning Manual

Supply units and power sections
Table of Contents

Advertisement

Project Planning Manual | Rexroth IndraDrive
6.3.3

Scope of Supply

6.3.4

Technical Data

Ambient and Operating Conditions

Description
Suitable for use on a circuit capable
of delivering not more than this
SCCR, symmetrical amperes (UL)
1)
rated input voltage, power (UL)
rated input current (UL)
3)
maximum output voltage (UL)
maximum output current (UL)
Description
listing according to UL standard
(UL)
UL files (UL)
listing according to CSA standard
(UL)
The scope of supply includes:
1 × touch guard
1 × connector X5 and X6 each
General Information
Conditions for transport and storage: see chapter
page
19.
Installation conditions: see chapter
This chapter contains:
limit values for use in the scope of C-UL
applied standards (CE conformity, UL listing)
UL Data
Ambient and operating conditions - UL ratings
Symbol
Unit
I
A rms
SCCR
U
V
2)
LN_nenn
I
A
L_cont
U
V
out
I
A
out_max
1)
600 V AC or less, use listed AC input line fuses or listed circuit breakers
2)
HMS, HMD, HLB, HLC, KCU: DC bus L+, L-; HMV, HCS: mains input
L1, L2, L3
3)
at PDC_cont
Fig.6-54:
HMS - Ambient and operating conditions - UL ratings
Information on Standards
Applied standards
Symbol
Unit
Fig.6-55:
HMS - Applied standards
Electric Drives
| Bosch Rexroth AG
and Controls
Power Sections for Inverters - IndraDrive M
4.3 Installation Conditions , page
HMS02.1N-W0028
42000
254...750
18,4
500
15,0
HMS02.1N-W0028
UL 508 C
E 134201
Canadian National Standard(s) C22.2 No. 14-05
145/369
4.2 Transport and Storage,
19.
HMS02.1N-W0054
30,7
25,0
HMS02.1N-W0054