Mounting The Accessory Has02; General Information - Bosch Rexroth IndraDrive HMV Project Planning Manual

Supply units and power sections
Table of Contents

Advertisement

348/369
Bosch Rexroth AG | Electric Drives
Accessories
11.3.6

Mounting the Accessory HAS02

General Information

CAUTION
and Controls
1
screw in thread XS2
2
fixing device of shielding plate
3
shielding plate
4
shield of motor cable
5
clip
Fig.11-43:
Shield connection of motor cable
Unscrew bottom or bottom left fixing screw of drive controller.
Put fixing device of accessories to bottom of drive controller and screw
down fixing screw of drive controller again.
Risk of damage to the drive controller caused by too long screws!
Exclusively use the supplied screws of a length of 12 mm for the thread of the
shield connection XS2.
Screw second screw (M6 x 12) in thread XS2 at bottom of drive controller.
Screw shielding plate to sheet metal of accessories according to desired
cable routing of motor cable (45° or horizontal). (The figure below illus‐
trates cable routing with 45°.)
According to diameter of motor cable, fix motor cable at corresponding
point of shielding plate (12–18 mm or 19–30 mm) with a clip. Make sure
that shield of motor cable has good contact with shielding plate (see figure
below).
Rexroth IndraDrive | Project Planning Manual