Bosch Rexroth IndraDrive HMV Project Planning Manual page 264

Supply units and power sections
Table of Contents

Advertisement

254/369
Bosch Rexroth AG | Electric Drives
Functions and Electrical Connection Points
and Controls
1
screw in thread XS2
2
sheet metal of accessories
3
fixing device
4
shield of motor cable
5
clip
Fig.8-16:
Strain relief, shield connection of motor cable with accessory HAS02 -
example HCS02
For optimum shield contact of the motor power cable, use our
accessory HAS02, where possible.
For the connection between drive controller and motor use our
ready-made motor power cables, where possible (see docu‐
mentation "Rexroth Connection Cables - Selection Data").
When using NFD03.1 mains filters, the maximum allowed con‐
ductor cross section is limited to 4 mm
For selecting the motor cables, observe the information con‐
tained in the section "Connection Cables to Motor" in the
documentation "Rexroth IndraDrive Drive System - Project
Planning Manual".
Rexroth IndraDrive | Project Planning Manual