Bosch Rexroth IndraDrive HMV Project Planning Manual page 164

Supply units and power sections
Table of Contents

Advertisement

154/369
Bosch Rexroth AG | Electric Drives
Power Sections for Inverters - IndraDrive M
current profile "UEL_I_e"
Description
maximum output current at
I
; f
= 2 kHz; t = 0,4 s;
out_base_1
s
T = 4 s; K = 2,5
1)
base load current at I
out_peak_1
f
= 2 kHz; t = 0,4 s; T = 4 s; K = 2,5
s
maximum output current at
I
; f
= 4 kHz; t = 0,4 s;
out_base_1
s
T = 4 s; K = 2,5
2)
base load current at I
out_peak_1
f
= 4 kHz; t = 0,4 s; T = 4 s; K = 2,5
s
maximum output current at
I
; f
= 8 kHz; t = 0,4 s;
out_base_1
s
T = 4 s; K = 2,5
3)
base load current at I
out_peak_1
f
= 8 kHz; t = 0,4 s; T = 4 s; K = 2,5
s
maximum output current at
I
; f
= 12 kHz; t = 0,4 s;
out_base_1
s
T = 4 s; K = 2,5
4)
base load current at I
out_peak_1
f
= 12 kHz; t = 0,4 s; T = 4 s; K = 2,5
s
maximum output current at
I
; f
= 16 kHz; t = 0,4 s;
out_base_1
s
T = 4 s; K = 2,5
5)
base load current at I
out_peak_1
f
= 16 kHz; t = 0,4 s; T = 4 s; K = 2,5
s
and Controls
Profile
Fig.6-65:
Definition of current profiles
Examples of allowed current profiles
Symbol
Unit
I
A
out_peak1_2
;
I
A
out_base1_2
I
A
out_peak1_4
;
I
A
out_base1_4
I
A
out_peak1_8
;
I
A
out_base1_8
I
A
out_peak1_12
;
I
A
out_base1_12
I
A
out_peak1_16
;
I
A
out_base1_16
Rexroth IndraDrive | Project Planning Manual
Explanation
The characteristic data of the profile are used to
select converters and inverters for operation with
standard motors and servo drives.
HMS02.1N-W0028
-
-
23,11
9,25
14,13
5,65
-
-
-
-
HMS02.1N-W0054
48,74
19,50
31,93
12,77
20,49
8,20
16,56
6,62

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents