Project Planning Manual | Rexroth IndraDrive
Description
power dissipation at I
out_cont
f
= f
(min.)
2)
s
s
power dissipation at I
out_cont
f
= f
(max.)
3)
s
s
power dissipation at continuous
current and continuous DC bus
power respectively (UL)
4)
minimum distance on the top of the
device
5)
minimum distance on the bottom of
the device
6)
temperature rise with minimum dis‐
tances d
; d
; P
bot
top
BD
Power Dissipation vs. Output Cur‐
Symbol
Unit
P
= 0 A;
W
Diss_0A_fsmi
n
P
= 0 A;
W
Diss_0A_fsma
x
P
W
Diss_cont
d
mm
top
d
mm
bot
ΔT
K
1)
also depending on firmware and control section; see Parameter De‐
scription "P‑0‑0001, Switching frequency of the power output stage"; see
"P-0-4058, Amplifier type data"
2) 3)
plus dissipation of braking resistor (at HMV, HCS) and control section
(at HMx, HCS); find interim values by interpolation to P_Diss_cont
4)
HMV, HCS: plus dissipation of braking resistor, control section; KSM:
plus rated power consumption control voltage input
5) 6)
see fig. "Air intake and air outlet at drive controller"
Fig.6-22:
HMS - Data for cooling and power dissipation
The figure below illustrates the connection between power dissipation and out‐
rent
put current, depending on the switching frequency f
controller. See also Parameter Description "P-0-0001, Switching frequency of
the power output stage".
In addition, take the power at the braking resistor and the power
consumption of the control section into account. Both powers are
not contained in the figure.
Electric Drives
and Controls
Power Sections for Inverters - IndraDrive M
HMS01.1N-
HMS01.1N-
W0110
W0150
60
70
160
130
640,00
965,00
35
| Bosch Rexroth AG
115/369
HMS01.1N-
HMS01.1N-
W0210
W0350
160
280
400
520
1570,00
2750,00
80
100
45
50