Coding of the Connectors
8.6.2
X5, Motor Connection HCS02.1E-W0012, -W0028 and HMS01.1N-
W0020, -W0036 and HMD01.1N-W0012...0036 and HMS02.1N-
W0028
View
Screw connection at connector
tightening torque
At the HMD power sections with two inverter outputs, the outputs
have been coded, i.e. provided with a coding section. This avoids
accidentally interchanging the two cables.
Coding
X5.1: coding section at pin 2
X5.2: coding section at pin 1
For ready-made Rexroth motor power cables, you therefore have
to change the coding of the male connector at the motor power ca‐
ble for X5.2, i.e. put the coding section at the male connector (not
at the female connector at the drive controller) from pin 1 to pin 2.
For X5.1, you do not need to change the coding of the male con‐
nector at the motor power cable.
Fig.8-17:
Coding of X5.1 and X5.2
Identifica‐
tion
A1
A2
A3
Unit
Nm
Electric Drives
| Bosch Rexroth AG
and Controls
Functions and Electrical Connection Points
Function
for power connection U1 at motor
for power connection V1 at motor
for power connection W1 at motor
for equipment grounding conductor of motor
Min.
0,5
255/369
Max.
0,6

Hide quick links: